Our standard cable items
There are more sheath material and outside diameter combinations possible with type T wire that displayed in the table. View our complete range on this overview page.
Thermocouple wire | Sheath material | MgO Insulation | Class | Outside Diameters | On stock | |
---|---|---|---|---|---|---|
Type T | AISI 304 | +98% Normal purity | Class 1 | 0.50 mm to 9.50 mm | Various diameters on stock | Send inquiry |
Type T | AISI 310(s) | +98% Normal purity | Class 1 | 0.50 mm to 9.50 mm | 18 week delivery time | Send inquiry |
Type T | AISI316(l) | +98% Normal purity | Class 1 | 0.50 mm to 9.50 mm | Various diameters on stock | Send inquiry |
Type T | AISI321 | +98% Normal purity | Class 1 | 0.50 mm to 9.50 mm | Various diameters on stock | Send inquiry |
Type T | Inconel 600 | +98% Normal purity | Class 1 | 0.50 mm to 9.50 mm | 18 week delivery time | Send inquiry |
Delivery times stated are for delivery to Kamet’s warehouse.
How can we help you today?
Request a quotation for the cable you need for your sensor.
Only high quality Okazaki AerOpak® MI cable
- Available in IEC EN60584 class 1, ASTM E230 special limits or AMS2750 E
- Manufactured according to IEC 61515 standards
- Comes with both a 3.1 certificate and a calibration certificate
- All raw materials originate from Europe, America, or Japan
- Supplied as coils, with the option to order straight lengths (which will have a bow or curvature)
- Standard wall thickness is at least 10% of the cable diameter, compliant with IEC61515; other specs available upon request
- Wire OD is at least 15% of the diameter for simplex, duplex, and triplex, compliant with IEC61515; contact us for other specs
- Can be bent around a mandrel with a radius equal to twice the sheath diameter without sheath rupture or loss of insulation resistance
- Sheath can be welded, brazed, and soldered without altering insulation resistance, using standard care for the metals and thickness
- Specific dimension tolerances like H9 are available upon request, following the ISO system of limits and fits
Type T thermocouple cable via Kamet
- Standard cables are available in stock with direct delivery.
- Non-stock items have a delivery time ranging from 10 to 18 weeks.
- Products are supplied either in whole coils or pieces.
- We offer delivery services in Europe and the Middle East.
- Customers have 24/7 access to our stock and pricing through our digital portal.
- A multilingual team is available to assist with questions about standard or custom solutions.
Approximate coil lenghts
Coil lenghts vary based on sheath materials. At the bottom of this page you will find a more detailed table with estimated coil lengths.
Outside diameter (mm) | Φ0.50 | Φ1.00 | Φ1.60 | Φ3.20 | Φ4.80 | Φ6.40 | Φ8.00 |
---|---|---|---|---|---|---|---|
Manufacturing maximum length (m) | 280 | 400 | 160 | 365 | 160 | 90 | 60 |
About Type T thermocouple
The Type T thermocouple is renowned for its high accuracy and stability, especially in low and cryogenic temperature applications. It is commonly used in the food industry due to its performance in moist environments without oxidizing. Made of Cu-CuNi, it operates effectively in temperatures below 0°C up to a maximum of 350°C (ASTM E230: 370°C), and is suitable for use in oxidizing, reducing, or inert gas atmospheres. However, it requires protection from contamination to prevent embrittlement, making it a reliable yet delicate tool for precise temperature measurements.
Type T thermocouple is also available as bare thermocouple wire.